chinese |  japanese |  thai

  • Application report 17 road portable ultrasonic flowmeter UFP

    2012-11-01 08:34 

          Application report 17 road portable ultrasonic flowmeter UFP - 20 (AR19) Tokyo KEIKI company. - - - - - - 2 path measuring 1 major unit - - - - - - this UFP - 20 portable, call to stop ultrasonic flowmeter provide 2 path measuring 2 double sensor in measuring point, cut off the flow state. Even though the customers want to use 2 path measurement, establish and fast installation and easy to such as shown above photos. In this special website, UFP - 20 portable meter and 2 double sensor stability measurement flow through a 150 mm diameter tube, non-intrusive, without interference from the outside of the flow.

          In this application, the client can try to restore to cut off the flow condition like turbulent due to short straight tube (close to the valve, elbow, door, branch, etc.). If so, 2 path measuring UFP - 20 can mean two data, measure each pair of sensor. So ultrasonic signal after different routes sensor a pair of double, 2 path measurement can choose the different speed factor from the asymmetric flow distribution.

          Therefore, 2 path function realizes stable flow measurement.

          This example highlights our handheld UFP - 20 ability clamp-on ultrasonic flowmeter.

          As demonstrates in the application (so, portable UFP - 20 meter used in combination to use all kinds of sensor can be successfully measuring pipe and nominal diameter from 13 mm to 5000 mm. UFP - 20 major unit internal memory can provide long term storage (record) of instantaneous flow rate and total according to - digital data, the data is then transferred to the computer through the USB memory in the CSV format and modification for statistical analysis and other purposes.

          pipe specification]

          Tube DN: 150 mm

          Tube material: carbon steel

          Hope: no
         [installation data)

         The main unit: portable ultrasonic flowmeter UFP - 10/20

         Sensor: medium sensor

         Installation: V method application report 17 road portable ultrasonic flowmeter UFP - 20 (AR19) zoom - 2 path measuring 1 major unit - - - - - -
         This UFP - 20 portable, call to stop ultrasonic flowmeter provide 2 path measuring 2 double sensor in measuring point, cut off the flow state.

         Even though the customers want to use 2 path measurement, establish and fast installation and easy to such as shown above photos.

         In this special website, UFP - 20 portable meter and

        2 double sensor stability measurement flow through a 150 mm diameter tube, non-intrusive, without interference from the outside of the flow.

         In this application, the client can try to restore to cut off the flow condition like turbulent due to short straight tube (close to the valve, elbow, door, branch, etc.). If so, 2 path measuring UFP - 20 can mean two data, measure each pair of sensor. So ultrasonic signal after different routes sensor a pair of double, 2 path measurement can choose the different speed factor

          From the asymmetric flow distribution.

          Therefore, 2 path function realizes stable flow measurement.

          This example highlights our handheld UFP - 20 ability clamp-on ultrasonic flowmeter.